Description
Folee 10l Oxygen Concentrator Price in Dhaka Bangladesh
ll plastic casing, safe and reliable. Real voice function. LCD screen. Remote-control function to operate remotely Cumulative time to show total working time by display. Single timer for real-time control once oxygen inhalation time. Timed shutdown function for easy use. Calendar function and more intuitive master of time. Button with back-light for clear and intuitive function display. Power-off alarm function Function of releasing anion. Heat protector equipped in the compressor. Oxygen concentration monitoring and alarming.
Our company is the noteworthy names engaged in exporting, manufacturing and supplying a huge spectrum of Folee New Design Oxygen Concentrator 1L 3L 5L large screen in Zhenjiang, Jiangsu, China. The oxygen concentrator is powered by 220V22V / 110V11V power source, takes the air as raw material, adopts the high-quality molecular sieve to make high-purity oxygen at normal temperature by pressure swing absorption separation (PSA).
Main Technical Specifications
Maximum flow3L / min
Flow scope when the nominal pressure at the outlet is 7kPa0.53L / min
Flow accuracy at maximum flow under the back pressure of 7kPa 10% of indicated flow
Outlet nominal pressure of 0 kPa Oxygen concentration 90%
Oxygen yield 0.5L/min3L/min
Output pressure0.02MPa0.07MPa
Release pressure of compressors safety valve280kPa 50kPa
Noise 60dB(A)
Power supply220V 22V / 110V11V
50Hz / 60Hz 1Hz
Input power400VA
Net weight13.5 kg
Dimension38.5 25.5 38 (cm)
Main technical specifications
- Recommended maximum oxygen flow: 5L/min.
- Flow scope when the nominal pressure at the outlet is 7kPa: 0.5L/min~9.9L/min.
- Apply 7kPa back pressure at the recommended maximum flow, the flow reaches accuracy of ± 10% to the indicated flow.
- Oxygen concentration when the nominal pressure at the output is zero (achieve the required oxygen concentration level within 30 minutes of the initial startup): the oxygen yield is 0.5L/min to 3L/min, the oxygen concentration is ≥90%.
Output pressure: 0.02MPa~0.07MPa - See Figure 1 for function table of oxygen concentration and oxygen flow when the nominal pressure at the output is zero.
- Release pressure of compressor’s safety valve: 280kPa±50kPa
- Noise: ≤ 60dB(A)
- Maximum nebulization rate: ≥ 0.1mL / min (for model with nebulizer)
- Power supply voltage: 220V±22V/110V±11V, 50Hz/60Hz ±1Hz
- Input power: 450VA
- Net weight: 17.42 kg
- Dimensions: 38.5×25×44(cm)
- Altitude: the oxygen concentration will not be reduced when it is from sea level to 1828m, but the oxygen concentration will be less than 90% when it is from 1828m to 4000m
- Safety system:
▲ Shutdown due to current overload or loose connections
▲ Shutdown due to high temperature of compressor;
▲ Low oxygen concentration alarm;
- Shortest working hours: not less than 30 minutes.
- Electrical classification: Class II equipment, type B application part
- Running mode: continuous operation
-
Normal working environment
▲ Ambient temperature range: 5 ℃to 40 ℃;
▲ Relative humidity range: ≤ 80%;
▲ Atmospheric pressure range: 860hPa to 1060hPa.
Notice: When the storage and transportation temperature is below 5℃, the oxygen concentrator shall be placed in normal working temperature for more than 4 hours before operation.
- Oxygen outlet temperature: ≤ 46℃
- Suggestion: the length of the oxygen tube shall not exceed 6 meters, and the oxygen tube can not be bent or deflated.
- Storage and transportation environment:
▲ Ambient temperature range: -40℃~+70 ℃;
▲ Relative humidity range: 10% to 100%, and no condensation;
▲ Atmospheric pressure range: 860hPa to 1060hPa.
Notice: The oxygen concentrator shall be stored inside the room where there is no strong sunlight,
No corrosive gases but well ventilated. Do not shake or place upside down the oxygen concentrator during transportation.
List of packaging
1. oxygen concentrator | 1 piece |
2. disposable nasal oxygen tube | 2 piece |
3. air filter | 1 piece |
4. fuse | 1 piece |
5. remote control | 1 piece |
6. O-shaped sealing ring of humidifier | 1 piece |
7. Operation Instruction |
Reviews